Services · Fire alarm systems

Fire alarm systems from design to maintenance – from one certified contractor.

Certified under DIN 14675 for every phase from design to maintenance. The responsible person is on our staff – not at an outside consultant.

A fire alarm system is not a product you buy and mount. It is a life cycle: design based on the fire safety concept, engineering with the inspector, installation during ongoing operation, commissioning, acceptance, then decades of maintenance. The German standard DIN 14675 divides this path into phases and requires a certified contractor with a named responsible person for each of them.

HD-Überwachung is certified for phases 6.1 to 11 (ZDS certification body for security technology, DAkkS-accredited; first certified 2022, recertified until 2030). The responsible person under DIN 14675 is the owner himself. For you that means one contact across the entire life of the system and no hand-over losses between designer, installer and maintenance contractor.

Scope

What we do in fire alarm technology

Design and engineering

  • Implementation of the fire safety concept and building authority requirements
  • Coordination with inspectors, fire brigade and insurers
  • Detector layout, loop planning, transmission path

Installation and conversion

  • New systems and extensions under DIN 14675 and DIN VDE 0833-2 using Telenot hifire
  • Conversion of existing systems during ongoing operation – other makes included
  • Cabling including fire stopping

Fire brigade interfaces and transmission

  • Fire brigade key safe, control panel and indicator panel
  • Transmission equipment and connection to monitoring centre or security provider
  • Fire brigade route cards and plans

Commissioning and acceptance

  • Configuration, functional testing, documentation
  • Preparation and support of the inspector's acceptance test
  • Operator training and hand-over of the logbook

Maintenance

  • Maintenance under DIN 14675 and DIN VDE 0833-1 with a service contract
  • Detector replacement per manufacturer specification, transmission path checks
  • Fault service for contract customers

Local alarms and smoke alarms

  • Local alarm systems for daycare centres, practices, smaller commercial buildings
  • Interconnected smoke alarms (Ei Electronics) for residential buildings
  • Fire stopping with building-authority approval

Systems we work with

New systems are built exclusively with Telenot hifire – we have been a trained Telenot installer for fire alarm, intrusion alarm and transmission systems since 2021. Existing systems of other makes we take over for maintenance or conversion where documentation and spare parts allow; we have the measuring and field-bus equipment for fault finding.

How it works

How a fire alarm project runs with us

Site visit and documents

We review the fire safety concept, building permit and existing system documentation and clarify what the inspector will want to see.

Concept and fixed price

Detector concept, transmission path, fire brigade interfaces – as a quote with items you can follow.

Installation during operation

Our own staff, our own aerial work platform, scheduling around your business. Fire stopping is done at the same time.

Acceptance and hand-over

We prepare the documentation, accompany the inspector's test and train your staff.

Subcontracting

For system integrators and general contractors

We have worked as a subcontractor for nationwide system integrators since 2018 and as an installation partner of Chubb since 2022. Installation, conversion, commissioning and service of alarm systems as a subcontractor – with all formal credentials (DIN 14675 certified contractor, responsible person, manufacturer training). Company profile with certificates on request.

References

Projects in this field

A selection. Private customers are listed without names; contact persons for project references on request.

HotelsBest Western Hotel Kaiserslautern

Fire alarm system, in-house fibre cabling, fire stopping and periodic DGUV V3 testing.

Hotel groupSAKS Urban Design Hotels

Fire alarm and security systems at several sites with ongoing support.

Church organisationsÖkumenische Gemeinschaftswerke

Fire alarm cabling at several sites.

BankingTARGOBANK

Complete cabling of several branches including fire detectors and video systems.

FAQ

What customers ask us about fire alarm systems

When is a fire alarm system mandatory in Germany?

When the building permit, the fire safety concept or the insurer requires it – typically hotels, assembly buildings, care facilities and larger commercial and industrial buildings. The fire safety concept states whether and what scope is needed; we go through it with you.

What does “certified contractor under DIN 14675” mean?

The standard requires a certified contractor with an examined responsible person for design, installation, commissioning, acceptance and maintenance. We are certified for all of these phases and present the certificates on request.

How often does a fire alarm system need maintenance?

Under DIN VDE 0833-1 at least one maintenance per year plus quarterly inspections, some of which the operator can carry out. The exact scope is defined in the maintenance contract.

Can you take over a system from another manufacturer?

In most cases yes. We check documentation, spare parts availability and condition and tell you openly whether taking it into maintenance makes sense or a conversion to Telenot would be more economical.

Do you work in English?

Yes. Site visits, quotes and documentation hand-over in English are no problem; the formal documents for the German inspector are produced in German as required.